Flat cable for moving equipments HO7VVH6-F

1,00

SKU: N/A Category:
Share on:

Description

N° conductors6912162024
N° conductors for group2X33X33X44X45X46X4
Section mm20,751,52,54610
Conductors resistance26,0013,307,984,953,301,91
Section mm216253550
Conductors resistance1,210,780,550,38
Nominal outer diameter -Tolerance +/- 0,5 mm
Construction
H – Harmonized cable
05 – Nominal tension 2 U0 /U: 300/500 V oppure/or
07 – Nominal tension 3 U0 /U: 450/750 V
V – Insulation with TI1 PVC
V – Outler sheath with TM2 PVC
H6 – Flatform cable with more than 4 conduct
F – Flexible conductors
F – Flexible conductors
R – Insulation with TI1 PVC
D – Flatform cable
R – Outler sheath with TM2 PVC
Identification
Cores identification according to CEI-UNEL 00722 tables; usually with progressive numbering, with or without green-yellow conductor: Blue outer sheath.
On request and for minimun quantitative or 3-4000 m, possibility of supplying with black outer sheath.
Standards
CEI 20-27 sigle di designazione
Tabella UNEL 35010 sigle di designazione
CEI 20-29/IEC 228 conductors for insulated cables
CEI 20-20/IEC 227 PVC insulated cable
CEI 20-35/IEC 332.1 Flame retardant
CEI 20-25/97 cavi flessibili piatti sotto guaina di PVC
Application
Cable used in moving equipment with shifting rate of 1.6 m/s. To be used at temparature ranging from -12°C and +80°C.

Additional information

SECTION

4X1.5, 8X1.5, 12X1.5, 16X1.5, 18X1.5, 20X1.5, 24X1.5, 4X2.5, 8X2.5, 12X2.5, 16X2.5, 18X2.5, 4X4, 4X6, 4X10, 4X16, 4X25, 4X35, 4X50

DIMENSIONS mm x mm

5.4X15.6, 5.4X29.1, 5.4X42.6, 5.4X56.1, 11.2X46.1, 11.4X47.1, 11.8X46.5, 6X19, 8.2X24.3, 6X52.6, 12.9X40.2, 11.6X51.6, 6.9X21, 7.7X24.2, 10.1X30.2, 11X35.4, 12.3X40.8, 15.4X49.9, 20.2X64.1

WEIGHT g / m

160, 310, 470, 630, 700, 780, 950, 220, 440, 650, 890, 1010, 330, 450, 720, 1100, 1550, 2100, 3150

mm2

6, 12, 18, 24, 27, 30, 36, 10, 20, 30, 40, 45, 16, 24, 40, 64, 100, 140, 200

CAPACITY max Amp

20, 27, 36, 48, 63, 85, 112, 138, 168